EasyManua.ls Logo

Cisco ONS 15454 ETSI - Install the Alarm Expansion Panel (ANSI Only)

Cisco ONS 15454 ETSI
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-46
Cisco ONS 15454 DWDM Procedure Guide, R8.0
78-17704-02
Chapter 1 Install the Shelf and Common Control Cards
NTP- G9 Install the Alarm Expansion Panel (ANSI Only)
NTP-G9 Install the Alarm Expansion Panel (ANSI Only)
Note The AIC-I card provides direct alarm contacts (external alarm inputs and external control outputs). In
the ANSI shelf, these AIC-I alarm contacts are routed through the backplane to wire-wrap pins
accessible from the back of the shelf. When you install an AEP, the direct AIC-I alarm contacts cannot
be used. Only the AEP alarm contacts can be used.
Step 1 Remove the two backplane screws. Replace the two screws with standoffs. Insert the longer standoff on
the left, and the shorter standoff on the right (Figure 1-21).
Purpose This procedure installs an AEP onto the 15454-SA-ANSI or 15454-SA-HD
shelf backplane. The AEP provides alarm contacts (32 inputs, 16 outputs)
in addition to the 16 provided by the AIC-I card. Typically, the AEP is
preinstalled when ordered with the ONS 15454 ANSI; however, the AEP
can be ordered separately. The AIC-I card must be installed before you can
provision the alarm contacts enabled by the AEP.
Tools/Equipment #2 Phillips Dynamometric screwdriver
Medium slot-head screwdriver
Small slot-head screwdriver
Wire wrapper
6-pair #29 AWG double-shielded cable
Standoffs (4)
Prerequisite Procedures DLP-G13 Remove the Lower Backplane Cover, page 1-28
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None

Related product manuals