EasyManua.ls Logo

Cisco ONS 15454 ETSI - Install the Y-Cable Protection Modules in the Y-Cable Module Tray

Cisco ONS 15454 ETSI
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-74
Cisco ONS 15454 DWDM Procedure Guide, R8.0
78-17704-02
Chapter 1 Install the Shelf and Common Control Cards
NTP- G377 Install the Y-Cable Protection Modules in the Y-Cable Module Tray
Step 1 According to the Cisco MetroPlanner Internal Connections Report, determine the Y-cable modules that
you want to install in the FlexLayer shelf.
Step 2 Insert the appropriate Y-cable module into the FlexLayer shelf assembly. Use a Phillips Dynamometric
screwdriver to install the two accompanying screws.
Step 3 Repeat Steps 1 and 2 as necessary for each Y-cable module you want to install. The FlexLayer shelf can
hold up to four Y-cable modules, and the Y-cable tray can hold up to eight Y-cable modules.
Step 4 Return to your originating procedure (NTP).
DLP-G377 Install the Y-Cable Protection Modules in the Y-Cable Module Tray
Step 1 According to the Cisco MetroPlanner Internal Connections Report, determine which slots you will use
to install the Y-cable modules.
Step 2 Open the drawer of the tray by pushing inward on the latches located at the left and right front of the tray.
Step 3 In the tray, pull up the latches on either side of the module frame and slide the frame upward until it is
fully extended.
Step 4 Line up the first Y-cable module that you want to install with the desired slot, pull the latch at the bottom
of the Y-cable module to enable the Y-cable module to slide onto the guides, and slide the module down
until it is fully installed in the slot. Figure 1-33 shows the Y-cable module that can be installed in the
Y-cable module tray.
Onsite/Remote Onsite
Security Level None
Purpose This task installs the Y-cable protection modules in the Y-cable module
tray. The Y-cable module tray can hold up to eight Y-cable modules.
Tools/Equipment #2 Phillips Dynamometric screwdriver
Y-cable modules: Multi-Mode Y-Cable Protection Module(s)
(15454-YCM-MM-LC) or Single-Mode Y-Cable Protection Module(s)
(15454-YCM-SM-LC), as appropriate
Cisco MetroPlanner Internal Connections Report
Prerequisite Procedures None
Required/As Needed As needed
Onsite/Remote Onsite
Security Level None

Related product manuals