The power specifications for the C210 M2 server are listed in Table 31.
Table 31 UCS C210 M2 Environmental Specifications
Parameter Minimum
Temperature operating 10°C to 35°C (50°F to 95°F)
Temperature nonoperating -40°C to 65°C (-40°F to 149°F)
Altitude operating 0 to 3,000 m (0 to 10,000 ft.); maximum ambient temperature decreases
by 1° per 300 m
Humidity nonoperating 5 to 93%, noncondensing
Vibration nonoperating 2.2 Grms, 10 minutes per axis on each of the three axes
Shock operating Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the
three axes
Shock nonoperating Trapezoidal, 25 G, two drops on each of six faces
Velocity = 175 inches per second on bottom face drop
Velocity = 90 inches per second on the other five faces
Electrostatic discharge Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV
contact discharge without physical damage
Acoustic Sound power: 54.7 dBA (5.7 Bels) at ambient temperature 23°C measured
using the Dome Method
GOST MsanPiN 001-96

Other manuals for Cisco UCS C210 M2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C210 M2 and is the answer not in the manual?

Cisco UCS C210 M2 Specifications

General IconGeneral
BrandCisco
ModelUCS C210 M2
CategoryServer
LanguageEnglish

Related product manuals