C-17
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
Appendix C RAID Controller Considerations
Embedded MegaRAID Controller
Note The noprobe values depend on the number of drives. For example, to install RHEL 5.7 on a
RAID 5 configuration with three drives, enter:
Linux dd blacklist=isci blacklist=ahci noprobe=ata1 noprobe=ata2 noprobe=ata3
Step 10 Press Enter.
The prompt asks whether you have a driver disk.
Step 11 Use the arrow key to select Yes , and then press Enter.
Step 12 Select fd0 to indicate that you have a floppy diskette with the driver on it.
Step 13 Do one of the following actions:
If you prepared the IMG file on a physical diskette in Step 2: Connect an external USB diskette drive
to the target server and then insert the diskette in the A:/ drive and press Ent
er.
If you mapped the IMG file as a virtual floppy in Step 5: Select the location of the virtual floppy.
The installer locates and loads the driver for yo
ur device. The following message appears:
Loading megasr driver...
Step 14 Follow the Red Hat Linux installation procedure to complete the installation.
Step 15 Reboot the system.
Installing the SUSE Linux Enterprise Server Driver
For the specific supported OS versions, see the Hardware and Software Interoperability Matrix for your
server release.
This section describes the installation of the SuSE Linux
Enterprise Server driver on a system with the
embedded MegaRAID stack.
Us e the following procedure to install the SLES drivers.
Step 1 Create a RAID drive group using the LSI SWRAID Configuration utility before you install this driver
for the OS. Launch this utility by pressing Ctrl+M when LSI SWRAID is shown during BIOS post.
Step 2 Prepare the dud.img file using one of the following methods:
To install from a physical diskette: Use one of the procedures in Preparing Physical Installation
Diskettes For Linux, page C-14.
Then return to Step 4 of this procedure.
To install from a virtual floppy disk: Download and save the Cisco UCS C-Series drivers ISO, as
described in D
ownloading the LSI MegaSR Drivers, page C-12.
Then continue with the next step.
Step 3 Extract the dud.img file:
a. Burn the ISO image to a disc.
b. Browse the contents of the drivers folders to the location of the embedded MegaRAID drivers:
/<OS>/Storage/Intel/C600/
c. Copy the dud-<driver version>.img file to a temporary location on your workstation.
Step 4 Start the Linux driver installation using one of the following methods:

Table of Contents

Other manuals for Cisco UCS C220 M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C220 M3 and is the answer not in the manual?

Cisco UCS C220 M3 Specifications

General IconGeneral
Tcase70 °C
Bus typeQPI
SteppingM1
FSB ParityNo
Scalability2S
Processor cache10 MB
Processor cores4
System bus rate6.4 GT/s
Processor seriesIntel Xeon E5-2600
Processor socketLGA 2011 (Socket R)
Processor codenameSandy Bridge EP
Processor frequency2.4 GHz
Processor cache typeSmart Cache
Processor manufacturerIntel
Processor package size52.5 x 45.0 mm
Processor front side bus- MHz
Processor boost frequency2.50 GHz
Processor operating modes64-bit
ECC supported by processorYes
Graphics & IMC lithography32 nm
PCI Express configurationsx4, x8, x16
Supported instruction setsAVX
Thermal Design Power (TDP)80 W
Number of processors installed2
CPU multiplier (bus/core ratio)24
Physical Address Extension (PAE)46 bit
Maximum number of PCI Express lanes40
Memory types supported by processorDDR3-SDRAM
Memory channels supported by processorQuad
Memory clock speeds supported by processor800, 1066 MHz
Memory bandwidth supported by processor (max)34.1 GB/s
Maximum internal memory supported by processor750 GB
HDD size2.5 \
HDD interface-
Total storage capacity500 GB
Compatible memory cardsSD
Maximum storage capacity- TB
Memory slots16
Internal memory32 GB
Memory clock speed1866 MHz
Maximum internal memory- GB
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Ethernet LAN (RJ-45) ports3
Chassis typeRack (1U)
Power supply450 W
SafetyUL 60950-1 No. 21CFR1040, CAN/CSA-C22.2 No. 60950-1, IEC 60950-1, EN 60950-1, IEC 60950-1, AS/NZS 60950-1, GB4943 2001
Certification47CFR Part 15 (CFR 47), AS/NZS CISPR22, CISPR2 2, EN55022, ICES003, VCCI, EN61000-3-2, EN61000-3-3, KN22, CNS13438, EN55024, CISPR24, EN300386, KN24
Operating altitude0 - 3000 m
Non-operating altitude0 - 12000 m
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 93 %
Operating relative humidity (H-H)10 - 90 %
PCI Express slots version3.0
Processor ARK ID64588
Intel Secure Key Technology version1.00
Intel Identity Protection Technology version0.00
Harmonized System (HS) code84714100
Weight and Dimensions IconWeight and Dimensions
Depth724 mm
Width430 mm
Height43.2 mm

Related product manuals