EasyManuals Logo

Cisco UCS C220 M3 Installation And Service Guide

Cisco UCS C220 M3
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #126 background imageLoading...
Page #126 background image
C-18
Cisco UCS C220 Server Installation and Service Guide
OL-25760-01
Appendix C RAID Controller Considerations
Embedded MegaRAID Controller
To install from local media: Connect an external USB DVD drive to the server and then insert the
first RHEL install disc into the drive. Skip to Step 6.
To install from remote ISO: Log in to the server’s CIMC interface and continue with the next step.
Step 5 Launch a Virtual KVM console window and select the Virtual Media tab.
a. Click Add Image and browse to select your remote RHEL installation ISO file.
b. Click Add Image again and browse to select your dud.img file.
c. Select the check box in the Mapped column for the media that you just added, then wait for mapping
to complete.
Step 6 Power cycle the server.
Step 7 Press F6 when you see the F6 prompt during bootup. The Boot Menu window opens.
Step 8 On the Boot Manager window, select the physical disc or virtual DVD and press Enter. The SLES
installation begins when the image is booted.
Step 9 When the first SLES screen appears, select Installation on the menu.
Step 10 Type one of the following in the Boot Options field:
For SLES 11 and SLES 11 SP1 (32- and 64-bit), type: brokenmodules=ahci
For SLES 11 SP2 (32-and 64-bit), type: brokenmodules=ahci brokenmodules=isci
Step 11 Press F6 for the driver and select Ye s.
Step 12 Do one of the following actions:
If you prepared the IMG file on a physical diskette in Step 2: Connect an external USB diskette drive
to the target server and then insert the diskette in the A:/ drive and press Ent
er.
If you mapped the IMG file as a virtual floppy in Step 5: Select the location of the virtual floppy.
“Yes” appears under the F6 Driver heading.
Step 13 Press Enter to select Installation.
Step 14 Press OK.
The following message appears: LSI Soft RAID Driver Updates added.
Step 15 At the menu, select the driver update medium and press the Back button.
Step 16 Continue and complete the installation process by following the prompts.

Table of Contents

Other manuals for Cisco UCS C220 M3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS C220 M3 and is the answer not in the manual?

Cisco UCS C220 M3 Specifications

General IconGeneral
Tcase70 °C
Bus typeQPI
SteppingM1
FSB ParityNo
Scalability2S
Processor cache10 MB
Processor cores4
System bus rate6.4 GT/s
Processor seriesIntel Xeon E5-2600
Processor socketLGA 2011 (Socket R)
Processor codenameSandy Bridge EP
Processor frequency2.4 GHz
Processor cache typeSmart Cache
Processor manufacturerIntel
Processor package size52.5 x 45.0 mm
Processor front side bus- MHz
Processor boost frequency2.50 GHz
Processor operating modes64-bit
ECC supported by processorYes
Graphics & IMC lithography32 nm
PCI Express configurationsx4, x8, x16
Supported instruction setsAVX
Thermal Design Power (TDP)80 W
Number of processors installed2
CPU multiplier (bus/core ratio)24
Physical Address Extension (PAE)46 bit
Maximum number of PCI Express lanes40
Memory types supported by processorDDR3-SDRAM
Memory channels supported by processorQuad
Memory clock speeds supported by processor800, 1066 MHz
Memory bandwidth supported by processor (max)34.1 GB/s
Maximum internal memory supported by processor750 GB
HDD size2.5 \
HDD interface-
Total storage capacity500 GB
Compatible memory cardsSD
Maximum storage capacity- TB
Memory slots16
Internal memory32 GB
Memory clock speed1866 MHz
Maximum internal memory- GB
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Ethernet LAN (RJ-45) ports3
Chassis typeRack (1U)
Power supply450 W
SafetyUL 60950-1 No. 21CFR1040, CAN/CSA-C22.2 No. 60950-1, IEC 60950-1, EN 60950-1, IEC 60950-1, AS/NZS 60950-1, GB4943 2001
Certification47CFR Part 15 (CFR 47), AS/NZS CISPR22, CISPR2 2, EN55022, ICES003, VCCI, EN61000-3-2, EN61000-3-3, KN22, CNS13438, EN55024, CISPR24, EN300386, KN24
Operating altitude0 - 3000 m
Non-operating altitude0 - 12000 m
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 40 °C
Storage relative humidity (H-H)5 - 93 %
Operating relative humidity (H-H)10 - 90 %
PCI Express slots version3.0
Processor ARK ID64588
Intel Secure Key Technology version1.00
Intel Identity Protection Technology version0.00
Harmonized System (HS) code84714100
Weight and Dimensions IconWeight and Dimensions
Depth724 mm
Width430 mm
Height43.2 mm

Related product manuals