General Parameters
Following are some general parameters for MegaCLI:
Adapter parameter aN
The parameter aN, where N is a number starting with zero or the string ALL, specifies the adapter ID. If
you have only one controller, you can safely use ALL instead of a specific ID, but you’re encouraged to use
the ID for anything that makes changes to your RAID configuration.
Physical drive parameter PhysDrv[E:S]
For commands that operate on one or more physical drives, the parameter PhysDrv[E: S] is used, where E
is the enclosure device ID in which the drive resides, and S is the slot number (stating with 0). The
enclosure device ID can be determined by using the command MegaCli Enclinfo aALL. The [E: S]
syntax is also used to specify the physical drives when you create a new RAID virtual drive
Virtual drive parameter Lx
The parameter Lx is used for specifying the virtual drive, where x is a number starting with 0 or the string
ALL.
Command Syntax
This section presents the syntax for common MegaCLI commands.
Commands to Get Information
Controller information:
MegaCli AdpAllInfo aALL
MegaCli CfgDsply aALL
MegaCli adpeventlog getevents f lsi-events.log a0 nolog
Enclosure information:
MegaCli EncInfo aALL
Virtual drive information:
MegaCli LDInfo Lall aAll
Physical drive information:
MegaCli PDList aAll
MegaCli PDInfo PhysDrv [E: S] aALL
Commands for Virtual Drive Management
Create a RAID volume based on a single drive group (RAID 0, RAID 1, or RAID 5):
MegaCli CfgLdAdd r (#raid level#) [E: S] aN
Create a RAID volume based on double drive groups (RAID 10 or RAID 50):
MegaCli CfgSpanAdd r (#Raid level#) Array0 [E: S, E: S] Array1 [E: S, E: S] aN
Figure 13 shows the creation of a double-drive-group RAID volume.