EasyManua.ls Logo

Cisco UCS C240 M3 - Low-Voltage DIMM Considerations; RAID Summary

Cisco UCS C240 M3
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cisco UCS C240 M3 High-Density Rack Server (Small Form Factor Disk Drive Model)
SUPPLEMENTAL MATERIAL
53
Low-Voltage DIMM Considerations
The C240 M3 server can be ordered with dual-voltage (1.35 V) DIMMs. Note the following considerations:
Low-voltage DIMMs within the server must have the identical manufacturer, type, speed,
and size.
Low-voltage DIMMs and standard-voltage DIMMs can be mixed in the same server. Note that
this causes the system BIOS to default to standard-voltage operation (Performance Mode).
That is, the server cannot operate in Power Saving Mode unless all DIMMs are low-voltage
DIMMs.
CPUs that have a maximum memory frequency less than 1333 MHz support low-voltage
DIMMs operating in Power Saving Mode only, and do not support Performance Mode.
RAID Summary
The C240 M3 SFF server can be ordered with a 16-drive backplane without a SAS expander or with a 24-drive
backplane with a SAS expander.
ROM5 and ROM 55 embedded RAID upgrade options support up to 8 drives with the 16-drive
backplane with no SAS expander and are not supported for the 24-drive backplane with the
SAS expander.
Mezzanine cards (UCSC-RAID-11-C240 and UCSC-RAID-MZ-240) support up to 8 drives for the
16-drive backplane with no SAS expander, and up to 16 drives for the 24-drive backplane
with the SAS expander
9266-8i and 9266CV-8i PCIe cards support up to 8 drives each for the 16-drive backplane with
no SAS expander, and up to 24 drives for 24-drive backplane with SAS expander
7 x 16 GB 7 112 GB 7 x 16 GB 7 112 GB 224 GB
8 x 16 GB 8 128 GB 8 x 16 GB 8 128 GB 256 GB
9 x 16 GB 9 144 GB 9 x 16 GB 9 144 GB 288 GB
10 x 16 GB 10 160 GB 10 x 16 GB 10 160 GB 320 GB
11 x 16 GB 11 176 GB 11 x 16 GB 11 176 GB 352 GB
12 x 16 GB 12 192 GB 12 x 16 GB 12 192 GB 384 GB
Notes . . .
a. Configurations for optimum memory performance are highlighted in yellow.
NOTE: If you do not select a mezzanine card, a plug-in PCIe RAID card, or one of the
embedded RAID upgrade options, you will have an embedded SATA-only RAID
controller that supports up to four SATA-only drives (RAID 0, 1, 10).
Table 28 Supported DIMM Configurations (continued)
a
CPU 1 DIMMs
Tota l
DIMMs for
CPU 1
CPU 1
Capacity
CPU 2 DIMMs
Tot al
DIMMs for
CPU 2
CPU 2
Capacity
Total
Capacity for
2 CPUs