The power specifications for the C240 M3 server are listed in Table 34.
Table 34 UCS C240 M3 Environmental Specifications
Parameter Minimum
Temperature operating 41 to 104° F (5 to 40° C)
derate the maximum temperature by 1°C per every 305 m of
altitude above sea level
Temperature nonoperating –40 to 149°F (–40 to 65°C)
Humidity (RH) operating,
non-condensing
10 to 90%
Altitude operating 0 to 3,000 m (0 to 10,000 ft.)
Altitude nonoperating 0 to 12,192 m (0 to 40,000 ft.)
Sound Power level, Measure
A-weighted per ISO7779 LWAd
(Bels)Operation at 73°F (23°C)
5.8
Sound Pressure level, Measure
A-weighted per ISO7779 LpAm
(dBA)Operation at 73°F (23°C)
43