NVMe Controller—This controller is used by servers in the Cisco UCS S3260 system for inventory
and firmware updates of NVMe disks.
For more details about the storage controllers supported in the various server nodes, see the related service
note:
Cisco UCS C3X60 M3 Server Node For Cisco UCS S3260 Storage Server Service Note
Cisco UCS C3X60 M4 Server Node For Cisco UCS S3260 Storage Server Service Note
Cisco UCS S3260 Storage Management Operations
The following table summarizes the various storage management operations that you can perform with the
Cisco UCS Manager integrated Cisco UCS S3260 system.
See:DescriptionOperation
"Disk Zoning Policies" section in this guide.The SAS expanders in the
Cisco UCS S3260 system can
manage the pool of drives at
the chassis level. To share
disks for high availability,
perform the following:
1. Creating disk zoning
policies.
2. Creating disk slots and
assigning ownership.
3. Associating disks to
chassis profile.
Disk Sharing for High
Availability
"Storage Profiles" section in the Cisco UCS
Manager Storage Management Guide, Release
3.1(2).
You can utilize Cisco UCS
Manager's Storage Profile and
Disk Group Policies for
defining storage disks, disk
allocation and management in
the Cisco UCS S3260 system.
Storage Profiles, Disk Groups
and Disk Group Configuration
Policies
"Removing Chassis Level Storage Enclosures"
section in this guide.
You can swap the HDD
expansion tray with a server,
or remove the tray if it was
previously inserted.
Storage Enclosure Operations
Cisco UCS S3260 System Storage Management
8
Cisco UCS S3260 System Storage Management
Cisco UCS S3260 Storage Management Operations

Other manuals for Cisco UCS S3260

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco UCS S3260 and is the answer not in the manual?

Cisco UCS S3260 Specifications

General IconGeneral
Drive BaysUp to 56
Maximum Storage CapacityUp to 600 TB
Power SupplyUp to 4 hot-plug power supplies
Product TypeStorage Server Chassis
Supported DrivesSAS, SATA
ProcessorsUp to two Intel Xeon Scalable processors
MemoryUp to 1.5 TB DDR4 RAM
Power SuppliesRedundant 80+ Platinum power supplies
Total Drive Bays56
ManagementCisco UCS Manager
CompatibilityCisco UCS system
Form Factor4U rack