E-13
Cisco UCS S3260 Storage Server Chassis Installation and Service Guide
 
Appendix E      Upgrading to Cisco UCS S3260 System With S3260 M5 Server Nodes
Installing a Second Server Node or SIOC to the S3260 System With M5 Server Node
• If you are not using a DHCP server, use the Cisco IMC interface (CLI or GUI) to manually assign 
a BMC IP address for the new server node. 
For example using the CLI:
S3260-Server# scope network
S3260-Server /cimc/network# set v4-addr-bmc<n> <v4 ip-address>
S3260-Server /cimc/network# set v6-addr-bmc<n> <v6 ip-address>
For more information see Cisco UCS C-Series Integrated Management Controller GUI 
Configuration Guide for S3260 Servers or the Cisco UCS C-Series Integrated Management 
Controller CLI Configuration Guide for S3260 Servers here: Configuration Guides.
The second M5 server node is now ready for use in the S3260 system.