7
EtherNet/IP Connection Procedure
49
7.5.2. Checking Sent and Received Data
Check that correct data is sent and received.
If you change the variable values on a Watch Tab Page when Sysmac Studio is
online with the CPU Unit, the devices connected to the Controller may operate
regardless of the operating mode of the CPU Unit.
Always ensure safety before you change the variable values on a Watch Tab
Page when Sysmac Studio is online with the CPU Unit.
1
With Sysmac Studio, select Watch
Tab Page from the View Menu.
2
The Watch (Project)1 Tab Page is
displayed.
3
Click Input Name and enter the
following variable names for
monitoring.
EIP002_MonitorCode_OUT[0]
(Monitor code 1)
EIP002_InputSignal_OUT[4]
(Bit 0: Monitor output
execution request)
EIP002_MonitorData_IN[0]
(Monitor data 1)
4
Select the display format for each
variable as follows:
EIP002_MonitorCode_OUT[0]:
Decimal
EIP002_InputSignal_OUT[4]:
Binary
EIP002_MonitorData_IN[0]:
Decimal