7
EtherNet/IP Connection Procedure
5
Check that the following online
values of the variables are
displayed.
EIP002_MonitorCode_OUT[0]:
0
EIP002_InputSignal_OUT[4]:
0000 0000
EIP002_MonitorData_IN[0]:
6
With AXTools, select the Monitor
Tab. The View of the Monitor Tab
is displayed. Select Motion from
the Ribbon Menu.
*If AXTools is not started, refer to
7.2.2. Parameter Settings to start
AXTools, then connect to
ABSODEX Driver again.
The Operation order menu Dialog
Box is displayed.
Check the value of Current
position (Actuator) in the Present
operation situation.
(450748 pulses in this example)
8
On the Watch Tab Page in
Sysmac Studio, enter 3 in the
Modify Column for
EIP002_MonitorCode_OUT[0].
The online value of
EIP002_MonitorCode_OUT[0]
changes to 3.
*For the above mentioned variable
(Monitor code 1), set the code
No. of the monitored item that is
selected to be fetched into
Monitor data 1.
Here, the code No. 3 is set as an
example, which indicates the
current position in full rotation