EasyManua.ls Logo

Clack Water Specialist WS1TC - User Manual

Default Icon
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Water Specialist
1” Control Valve Series Model: WS1TC
1.25” Control Valve Series Model: WS1.25TC
Operation and Instruction Manual for OEM Only.
Please Note: This operation and instruction manual is for the training of
the OEM and for the OEM to use to train their customers. This document
is not to be used as the complete system manual.
TÜRK
SU ARAŞTIRMA
MERKEZİ
Turkish
Water
Association
Ayrıntılı Bilgi ve Sipariş için :
e-mail : bilgi@tusam.com.tr
web : www.tusam.com.tr
Phone : +90 850 302 0 392

Questions and Answers

  • J
    Jared FarrellAug 3, 2025
    Why is my Clack Control Unit timer displaying the wrong time?
    • H
      Howard BanksAug 3, 2025
      If the Clack Control Unit timer isn't displaying the correct time of day, it might be due to a switched outlet. To resolve this, ensure you are using an uninterrupted outlet. It could also be caused by a power outage, in which case you should reset the time of day. In some cases, a defective PC board can be the reason, and the solution is to replace it.
  • C
    cynthiawhiteAug 8, 2025
    How to fix Clack Control Unit timer not displaying time of day?
    • A
      Andrea MillerAug 8, 2025
      If the Clack Control Unit timer isn't displaying the time of day, first, ensure the AC adapter is properly connected to a power source. If it is, check that the outlet has electric power; repair the outlet or try a different one if necessary. If the problem persists, the AC adapter may be defective and need replacement. As a last resort, the PC board could be defective, requiring replacement.
  • M
    Mario RoseAug 13, 2025
    Why does my Clack Control Unit valve regenerate at the wrong time?
    • A
      andrea15Aug 13, 2025
      If the Clack Control Unit valve regenerates at the wrong time, it could be due to several reasons. Power outages can cause this, so reset the control valve to the correct time of day. Also, the time of day might not be set correctly, so ensure you reset it. Finally, the regeneration time itself might be incorrect, requiring you to reset it to the proper time.
  • N
    Nicole DelacruzAug 18, 2025
    What to do if Clack Water Specialist WS1TC valve doesn't regenerate when pressing UP and DOWN buttons?
    • J
      Jermaine VanceAug 18, 2025
      If your Clack Control Unit valve doesn't regenerate automatically when you press and hold the UP and DOWN buttons, start by checking the AC adapter to ensure it's properly connected. Next, verify that the outlet has power; repair the outlet or try a different one if needed. If those aren't the issue, the drive gear or drive cap assembly might be broken, requiring replacement. Lastly, a defective PC board could be the cause, which would also need replacement.
  • V
    Vanessa WhiteAug 22, 2025
    What causes a Clack Water Specialist WS1TC Control Unit valve to stall during regeneration?
    • B
      Bridget SmithAug 23, 2025
      If your Clack Control Unit valve is stalled during regeneration, there are several potential causes: 1. The motor might not be operating, in which case you should replace it. 2. There may be no electric power at the outlet, so repair the outlet or use a working one. 3. The AC adapter could be defective, requiring replacement. 4. The PC board might be defective, and you'll need to replace it. 5. The drive gear or drive cap assembly could be broken, necessitating replacement. 6. A broken piston retainer could be the culprit, so replace it. 7. Finally, the main or regenerant piston might be broken, requiring replacement.
  • L
    Lori MartinezAug 28, 2025
    Why Clack Water Specialist WS1TC Control Unit valve regenerates manually but not automatically?
    • D
      Donald MartinezAug 28, 2025
      If your Clack Control Unit valve does not automatically regenerate (but does when you press and hold the UP and DOWN buttons), it could be due to a defective PC board, which would require replacement. Alternatively, there may be a set-up error, so double-check the control valve set-up procedure.

Summary

Control Valve Operation

Manual Regeneration

Step-by-step guide for initiating manual regeneration.

Introduction and Safety

General Warnings

Essential safety precautions and operating guidelines for installation and use.

Specifications

Quick Reference Specifications

Summary of key technical specifications for the control valve.

Control Valve Functionality

Bypass Valve Functionality

Bypass Valve Operation Positions

Explanation of the four bypass valve positions.

System Configuration and Setup

OEM System Setup

Step-by-step guide for initial system configuration.

Installer Settings

Procedures for installer display and regeneration settings.

Installation and Troubleshooting

Power Loss and Error Handling

Procedures for power outages and error messages.

Flow Diagrams

Service and Backwash Flow

Diagrams illustrating service and backwash water flow.

Flow Diagrams - Regeneration Cycles

Downflow Brine and Rinse Flow

Diagrams illustrating brine and rinse flow.

Flow Diagrams - Fill Cycle

Fill Flow

Diagram illustrating the fill cycle water flow.

Service Instructions

Drive Assembly Service

Instructions for servicing the drive assembly.

Service Instructions - Drive Components

Service Instructions - Internal Components

Service Instructions - Refill and Plug

Service Instructions - Valves

Component Identification

Injector Performance Graphs

US Units Flow Rates

Graphs showing injector flow rates in US units.

Injector Performance Graphs - Metric Units

Metric Units Flow Rates

Graphs showing injector flow rates in metric units.

Limited Warranty

Clack Corporation Five-Year Limited Warranty

Details of the product warranty terms.

Clack Water Specialist WS1TC Specifications

General IconGeneral
ModelWS1TC
TypeControl Unit
Valve Size1"
Operating Pressure20 - 125 psi
DisplayLCD
Timer TypeElectronic
Cycle SettingsAdjustable
BypassOptional
Valve MaterialNoryl
Inlet/Outlet1" NPT
ManufacturerClack
Valve TypeTime Clock
Operating Temperature34 - 120°F (1 - 49°C)
MaterialsNoryl
Drain Line1/2" NPT
Brine Line3/8"
Riser Tube Diameter1.05"

Related product manuals