SYMPTOM PROBABLE CAUSES REMEDY
Condensation at outlet Piping installation incorrect. Consult your local dealer.
points. Compressor taking in air Obtain better fresh-air
which is too warm. supply for compressor.
Delivery temperature of air a) Use a larger air receiver.
from air receiver too high. b) Contact Clarke Service
Department.
Electric Motor too hot: Operational voltage too low. Call an electrician.
maximum temperature Faults in electrical installation Contact Clarke Service
90 C (194 F). Department
Cooling fins of electric motor Clean cooling fins.
blocked by dirt.
Machine running but Air exhausting from solenoid Check solenoid valve.
not pumping air into after starter has changed from Contact Clarke Service
receiver (10 HP and star to delta. Department
above).
13
Spare Parts and Service
For spare parts and service, please contact your nearest dealer, or
Clarke International, on one of the following numbers.
PAR TS & SERVICE TEL.: 020 8988 7400
PAR TS & SERVICE FAX: 020 8558 3622
or e-mail as follows:
PAR TS: parts@clarkeinternational.com
SERVICE: service@clarkeinternational.com

Other manuals for Clarke PEVH11C50

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Clarke PEVH11C50 and is the answer not in the manual?

Clarke PEVH11C50 Specifications

General IconGeneral
BrandClarke
ModelPEVH11C50
CategoryAir Compressor
LanguageEnglish

Related product manuals