EasyManuals Logo

Clarke PLS265 User Manual

Clarke PLS265
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
15
Parts & Service: 020 8988 7400 / E-mail: Parts@clarkeinternational.com or Service@clarkeinternational.com
APPLYING CHEMICALS AND CLEANING SOLVENTS
1. Push the chemical hose onto the
ridged fitting as shown.
2. Place the other end of the
chemical hose with the filter on it,
into a container holding the
chemical/cleaning solution.
3. Slide the nozzle forward for low
pressure operation.
The water/chemical ratio is
typically
7:1, for every 7 gallons of water pumped 1 gallon of
chemical/ cleaning solution will be used.
SHUTTING DOWN
1. After each use, if you have applied chemicals, place the chemical hose
into a container of clean water and run clean water through the chemical
injection system to flush the system thoroughly.
NOTE: Failure to do so could cause damage to the pump.
2. Turn the engine off. See engine owner's manual.
NOTE: NEVER
turn the water off with the engine running.
3. Turn the water supply off.
4. Pull the trigger on the spray gun to relieve any
water pressure.
5. See storage section in this manual for proper storage procedures.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Clarke PLS265 and is the answer not in the manual?

Clarke PLS265 Specifications

General IconGeneral
BrandClarke
ModelPLS265
CategoryPressure Washer
LanguageEnglish

Related product manuals