SHUTTING DOWN
1. Reduce engine speed to minimum using the throttle lever.
2. Stop the engine by switching OFF the ignition switch.
3. Close the fuel valve.
MAINTENANCE
1. Always maintain the pump in a clean condition, checking regularly for
loose bolts etc.
2. Clean the air filter once every 50 hours of use (or more often in unusually
dusty conditions) as follows.
3. Unscrew the wingnut and lift off the air filter assembly from the engine.
4. Remove the components shown
and clean the foam filter element
with a high flashpoint solvent.
Squeeze dry, then dip in clean
engine oil and squeeze oil excess
oil.
Never operate the pump
without the air cleaner installed
as this would cause premature
wear to the engine.
5. Replace the spark plug after the
first month or every 50 hours of
use.