CleanSpace Respirators USER INSTRUCTIONS
24
IF A SATISFACTORY FIT CANNOT BE ACHIEVED, DO NOT ENTER THE CONTAMINATED AREA
Switch the Power Unit to Standby Mode by pressing the
Power Button once.
Connect Power Unit to mask.
Position the Power Unit around back of
neck. Ensure filter cover hoop is facing
upwards.
Connect left mask AirClip to left Power
Unit AirClip. Inhale to activate to the
breath responsive Power Unit.
If the Power Unit does not activate, it
may have been in Off Mode. Unclip the
Power Unit from mask to remove.
Briefly press the Power Button to
activate Standby Mode and connect
again as described above.
Connect right mask AirClip to right
Power Unit AirClip.
If unable to connect both AirClips to the Power Unit, ensure both bellows are extended and try again.
Connect harness to filter cover hoop.
Reach behind head and locate harness
rear strap. Locate the hook at end of
strap. Snap the hook onto filter cover
hoop. Harness now supports the weight
of the Power Unit.
Adjust Power Unit position.
Adjust the rear strap to set the height of
the Power Unit.
For most users, wearing the Power Unit
level is comfortable.
If your job involves looking up a lot (for
instance sanding a ceiling), you may
prefer to tighten the strap to raise the
Power Unit.
Note Orientate the
power unit with the
keypad facing up