EasyManua.ls Logo

CleanSpace EX - Limitations of Use

CleanSpace EX
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CleanSpace Respirators USER INSTRUCTIONS
4
English
5. Limitations of Use
Use the CleanSpace Respirator strictly in accordance with these User Instructions. DO NOT modify or alter this product.
DO NOT USE for respiratory protection against unknown atmospheric contaminants, when concentrations of
contaminants are unknown, or immediately dangerous to life or health (IDLH).
Do not use if the oxygen concentration is below 19.5%.
Do not remove the CleanSpace Respirator until you have left the contaminated area, unless you have pressing health
reasons to do so, (for instance you are experiencing dizziness and believe removing the respirator while leaving the
contaminated area may help).
Only suitable for use by clean-shaven personnel. Facial hair under the seal reduces protection and is not permitted.
Unless used with a CleanSpace Full Face Mask, the CleanSpace respirator DOES NOT PROTECT YOUR EYES. In conditions
that may damage or irritate eyes, use protective eyewear.
Only use CleanSpace approved filters and accessories.
Do not use the CleanSpace Respirator unless it is powered and running normally.
Do not use the CleanSpace Respirator while it is connected to the charger.
Do not use in airborne contaminant concentrations above those specified by your national regulations.
Only for use by trained personnel.
Filters need to be changed regularly. The frequency of filter changes depends on CleanSpace Respirator use and on the
concentration of contaminants in the environment.
Do not use for escape purposes.
National regulations may impose specific limitations on the use of filters depending on the filter class and the facemask
used.
LEAVE THE CONTAMINATED AREA IMMEDIATELY IF:
CleanSpace Respirator warning lights or sounds activate for the Low Battery Alarm or the Blocked Filter Alarm
Any part of the respirator is damaged
Air flow into the mask decreases or stops
Breathing becomes difficult or increased resistance occurs
You feel dizzy or your airway is irritated
You can taste or smell contaminants
Your CleanSpace Respirator is suitable for use in the following atmospheric conditions:
Temperature: -10°C to 45°C (Note: Explosive atmospheres approvals apply up to maximum ambient temperature of
40°C).
Relative humidity: 0 to 90% non-condensing.
The CleanSpace Respirator will stop functioning if its internal temperature rises above 60°C (ambient 50°C) or falls below -
10
°
C.
If the CleanSpace Respirator has become contaminated with a substance requiring special decontamination procedures, it
should be sealed in a suitable container until it can be decontaminated.
Do not disassemble the CleanSpace Respirator case. There are no user serviceable parts inside.
Failure to follow all instructions on the use of this product may render the warranty void.
Failure to use the CleanSpace Respirator properly during times of exposure may lead to adverse effects on the wearers health.

Related product manuals