CleanSpace Respirators USER INSTRUCTIONS
9
English
The Low Battery Alarm cannot be muted.
Battery life is strongly affected by work rate, atmospheric pressure, and other factors. The approximate operating times
stated in Section 13. Battery Information are typical for moderate work rates at sea level. Actual operating times may vary
widely.
FILTER WARNING ALARM
The Filter Warning Alarm is triggered if the filter is blocked. The Filter Warming Alarm consists of two (2) beeps,
repeated once per second, and the red LED flashes.
The Filter Warning Alarm can be muted for 15 minutes by pressing the Power Button once.
If the Filter Warning Alarm is triggered, you must move out of the contaminated area IMMEDIATELY and change the filter.
8. Using the CleanSpace Respirator with Half Mask
MASK FITTING FOR HALF MASK
Intrinsically Safe
NOT Intrinsically Safe
PAF-0064 EX Half Mask Small
PAF-0062 EX Half Mask Medium
PAF-0063 EX Half Mask Large
PAF-0033 Half Mask Small
PAF-1010 Half Mask Medium
PAF-0027 Half Mask Large
Determine the correct mask size and achieve a good fit prior to using the CleanSpace Respirator.
Mask fitting must be carried out by a specialist / designated mask fitter. The fit must be confirmed by a quantitative fit test.
To carry out a quantitative fit test the specialist / designated mask fitter will require the PAF-0025 PortaCount Adaptor and
the accompanying S005-7174 Quantitative Fit Test Instructions. The PortaCount Adaptor is an accessory that fits between the
mask and exhalation valve, allowing the air in the mask to be sampled.
No PAPR can fully protect you if you are not clean shaven. CleanSpace Respirator is not suitable for users with facial hair.
MASK SELECTION GUIDELINES
No set of guidelines can ensure a good fit. Fit must be confirmed with a quantitative fit test. The table below is a guideline
for the specialist / designated mask fitter.