The security system will ignore the input that was active when the sys-
tem was armed, until the input goes away. Three seconds later the sys-
tem will monitor that input normally. For example, if your vehicle has
the boot open, and you arm the system, you will hear Bypass
Notification chirps. Once you shut the boot, however, it is then moni-
tored normally.
disarming diagnostics
Extra disarm chirps are the Tamper Alert warning. If you hear three
chirps when disarming, the system was triggered in your absence. If
three chirps are heard, the LED status indicator will indicate which zone
was triggered when you turn the ignition on (see the Table of Zones
section). The system will retain this information in its memory. Refer to
the Multiple Event Total Recall section of this guide.
arm/disarm diagnostic chart
Action Chirps Light Flashes Description
Arm 2 2 System armed
Arm 4 4 System armed with boot or
bonnet active and
bypassed (zones 5 and 6)
Arm 2 (5 sec.) 4 2 (5 sec.) 4 System armed with door
active and bypassed (zone 4)
Arm 2 (10 sec.) 4 2 (10 sec.) 4 System armed with sensor
active and bypassed zones
(1, 2, 3, and 8)
Disarm 3 3 System disarmed with
tamper alert
Disarm 1 1 System disarmed
Disarm 1 (low pitch) 1 System disarmed with trans-
mitter low battery warning
G919730P_01-07.qxd 1/12/07 3:39 PM Page 16