EasyManuals Logo

ClimateMaster ATM11C11 User Manual

ClimateMaster ATM11C11
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
5
THE SMART SOLUTION FOR ENERGY EFFICIENCY
ATA11U03
Rev.:09/16/13
Conguration
Conguration
Congurationoptionsenabletheinstallertocongure
thethermostatforaparticularinstallation.These
congurationoptionsarestoredtotheinternal
memorysotheyareretainedthroughapoweroutage.
Theavailabilityofsomecongurationoptionswillbe
dependentuponotherconditionsinthethermostat.
Table 1: Conguration Options Summary
Entering and Exiting Conguration Mode-Pressand
holdthefanbuttonforabout10seconds.Afterthe10
secondperiodtheOptionnumber“02”willappear
ashinginthespacetemperaturelocation.Thevalueof
thecongurationsettingwillbedisplayedinthesetpoint
location.
Theparameterthatischangeablewillbedeterminedby
theashingarea.Theupordownbuttonscanbeused
toselectanewvalue.Themodebuttoncanbeusedto
toggle/movetheselectionbetweentheconguration
optionnumberandthecongurationvalue.Toexitthe
installercongurationscreen,pressthefanbutton.If
nobuttonispressedforthreeminutes,theinstaller
congurationscreenwilltimeoutandthethermostatwill
returntonormaloperation.
Allchangestotheinstallercongurationaresavedas
theyaremade.Thereisnoprovisiontoexittheinstaller
congurationandcancelthechange.Theinstallerwill
havetomanuallychangeacongurationbacktoits
originalvalueto“undo”achange.
Conguration Options
OPTION 02 — REMOTE SENSOR SELECTION — A
remotesensor17B0008N05(forinsideduet),orASW06
(forwall)canbeconnectedtotheS1andS2screw
terminalstosenseeitherremotespace,returnair,
outdoorair,orsupplyairtemperature.
Selection:rA,Od,SA,rS
rA*—Sensereturnairtemperature
*Displayonly,notusedfortemperaturecontrol.
Od*—Senseoutdoorairtemperature
SA*—Sensesupplyairtemperature
rS—Senseremotespacetemperature
Default:rS
Note: Option 02 cannot be changed from the rS setting
if Option 05 is set to either r or Lr.
OPTION 03 — ENGLISH/METRIC—Thisconguration
selectsbe-tweenFahrenheit(F)andCelsius(C)operation.
Selection:F,C
Default:F
OPTION 05 — SPACE TEMPERATURE SENSING
This selection determines which sensor the control
willuseformeasuringspacetemperature.Space
temperaturecanbesensedinoneofthreeways:the
localsensor(L)locatedonthethermostat,theremote
sensor(r),ortheaverageoflocalandremotesensors(Lr).
Selection:L,r,Lr(Donotuse)
L—Localsensor:Theonboardthermistoristhe
controlpointforthetemperaturecontrolalgorithm.
r—Remotespacesensor:Theremotespace
temperatureisthecontrolpointforthetemperature
control algorithm.
NOTE: This selection is only available if Option 02
indicates that the S1, S2 terminals are sensing a
remote space temperature.
Default:r
WARNING!
WARNING! User should not recongure installer set up.
Equipment damage could occur.
NOTICE
Wall thermostat requires congurating for on board sensing.
Installer must congure 05 to L unless remote sensor
is used.
Option
Number
Conguration Default
02 Remote Sensor Selection rS
03 English/Metric F
05 Space Temperature Sensing r
07 Equipment DDC Controller OF
11 Deadband between Heating and Cooling Set Points 5
13 Space Temperature Display Adjustment (Offset) 0
15 Auto Mode Availability ON
16 Maximum Cycles Per Hour 4
18 Backlight Conguration OF
20 Outdoor Air Temperature Adjustment (Offset) 0
21 Keypad Lockout OF
26 Minimum Cooling Set Point 60
27 Maximum Heating Set Point 85
39 Temperature Display St
40 Fan Speeds Selection 2

Other manuals for ClimateMaster ATM11C11

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ClimateMaster ATM11C11 and is the answer not in the manual?

ClimateMaster ATM11C11 Specifications

General IconGeneral
BrandClimateMaster
ModelATM11C11
CategoryThermostat
LanguageEnglish

Related product manuals