Tranquility
®
30
(TT) Series
Models TTD/H/V 026 - 072
60 Hz - HFC-410A
INSTALLATION, OPERATION,
& MAINTENANCE
97B0075N05
Revised: 18 July, 2013
Table of Contents
Model Nomenclature 3
Unit Physical Data 6
Horizontal Installation 7
Field Conversion of Air Discharge 9
Horizontal Installation 10
Vertical Installation 11
Piping Installation 13
Water-Loop Heat Pump Applications 14
Ground-Loop Heat Pump Applications 15
Ground-Water Heat Pump Applications 17
Water Quality Standards 19
Electrical - Line Voltage 20
Electrical - Power Wiring 22
Electrical - Power & Low Voltage Wiring 23
Electrical - Low Voltage Wiring 24
Electrical - Thermostat Wiring 26
Blower Performance Data 27
ECM Blower Control 28
Typical Wiring Diagram - Units with CXM Board
and ECM Fan Motor (Single Phase) 30
Typical Wiring Diagram - Units with
ClimaDry
®
(Single Phase) 31
Typical Wiring Diagram - Units with CXM Board, 32
ECM Fan Motor, and MPC (DDC) CONTROLS
(SINGLE PHASE) 32
CXM Controls 33
DXM Controls 34
Safety Features - CXM and DXM Controls 36
ClimaDry
®
Modulating Reheat Option 38
Unit Starting and Operating Conditions 41
Piping System Cleaning and Flushing 42
Unit and System Checkout 44
Unit Start-Up Procedure 45
ClimaDry
®
II Option Corrections
(When Operating in Non-ClimaDry
®
Mode) 46
Unit Operating Conditions 47
Preventive Maintenance 49
Functional Troubleshooting 50
Performance Troubleshooting 51
Start-Up Log Sheet 52
Functional Troubleshooting 53
Warranty (U.S. & Canada) 54
Warranty (International) 55
Revision History 56

Questions and Answers:

ClimateMaster Tranquility TTD026 Series Specifications

General IconGeneral
BrandClimateMaster
ModelTranquility TTD026 Series
CategoryHeat Pump
LanguageEnglish

Summary

Installation, Operation, and Maintenance

Model Nomenclature

ClimaDry II Option Notes

Notes regarding the ClimaDry II option, detailing its requirements and limitations.

General Information

Safety Precautions

Covers DANGER, WARNING, CAUTION, and NOTICE statements for safe operation and handling.

Equipment Inspection and Storage

Guidelines for inspecting shipments, safe storage practices, and unit protection on job sites.

Pre-Installation Procedures

Installation Cautions

Important warnings and cautions related to unit installation, handling, and storage.

Unit Physical Data

Water Working Pressure Limits

Table detailing maximum allowable water pressure for various unit options.

Horizontal Installation

Horizontal Unit Location Guidelines

Recommendations for selecting an appropriate indoor location for horizontal unit installation.

Mounting Horizontal Units

Instructions on how to properly suspend and pitch horizontal heat pump units.

Installation Notes for Ducted Returns

Important notes regarding ducted return air applications for horizontal units.

Field Conversion of Air Discharge

Side to Back Discharge Conversion

Procedure for converting the air discharge from side to back configuration.

Left vs. Right Return Configuration

Explanation regarding the limitations and possibilities of field converting return air configurations.

Horizontal Installation Specifics

Condensate Piping for Horizontal Units

Guidelines for installing condensate drain lines for horizontal units, ensuring proper drainage.

Duct System Installation Best Practices

Recommendations for designing duct systems to ensure optimal unit performance and quiet operation.

Vertical Installation

Vertical Unit Location Guidelines

Recommendations for selecting an appropriate mechanical room or closet for vertical unit installation.

Vertical Sound Attenuation

Methods for achieving sound attenuation for vertical units installed in mechanical rooms or closets.

Condensate Piping for Vertical Units

Instructions for condensate line installation for vertical units, including trap requirements.

Piping Installation Procedures

Supply and Return Piping Guidelines

Detailed guidelines for installing supply and return piping, including valve and union placement.

Installer Cautions for Water Connections

Cautions for installers regarding water connections, especially for ClimaDry® equipped units.

Water-Loop Heat Pump Applications

Commercial Water Loop Applications

Information on connecting multiple units to a common piping system for commercial applications.

Low Water Temperature Cutout Settings

Guidance on selecting low water temperature cutout settings for CXM controls with antifreeze.

Ground-Loop Heat Pump Applications

Pre-Installation for Ground Loops

Steps for locating and marking underground utilities before installing ground loops.

Antifreeze Requirements and Selection

Information on when antifreeze is required and how to calculate the correct concentration.

Ground-Water Heat Pump Applications

Water Quality Standards and Assessment

Guidelines for assessing water quality and potential scaling using pH/Calcium hardness methods.

Water Control Valve Placement and Operation

Notes on water control valve placement to prevent mineral precipitation and reduce water hammer.

Electrical - Line Voltage

General Line Voltage Wiring

Ensuring available power matches unit specifications and wiring complies with codes.

Transformer Wiring for Voltage Settings

Instructions for rewiring the transformer for 230V supply voltage on 208/230V units.

Electrical - Power Wiring

Power Connection Procedures

Connecting incoming line voltage wires to the contactor side for power supply.

Transformer Wiring Adjustments

Procedure for adjusting transformer wiring for specific supply voltages like 230V.

Electrical - Power & Low Voltage Wiring

Low Voltage Wiring and Thermostat Connections

Guidelines for low voltage wiring and connecting thermostats to the unit control board.

Low Water Temperature Cutout Selection

Field selection of low water temperature limits using jumpers on the control board.

Electrical - Low Voltage Wiring Details

Water Solenoid Valve Operation

Using external solenoid valves for ground water installations to shut off flow and reduce water hammer.

Two-Stage Unit Piping for Water Valves

Piping recommendations for two-stage units using parallel solenoid valves for water flow regulation.

Electrical - Thermostat Wiring

Thermostat Installation Guidelines

Recommendations for thermostat location and mounting to ensure accurate temperature measurement.

Blower Performance Data

ECM Blower Control

CFM Adjust Settings

Adjusting fan speed settings (CFM) via DIP switches or jumpers for optimal airflow.

Dehumidification Mode Settings

Configuring the unit for dehumidification mode to improve moisture removal efficiency.

Typical Wiring Diagrams

CXM Board & ECM Fan Motor Wiring

Wiring diagram for units with CXM board and ECM fan motor (single phase).

ClimaDry® (Single Phase) Wiring

Wiring diagram for units equipped with ClimaDry® (single phase).

CXM, ECM Motor, MPC (DDC) Controls Wiring

Wiring diagram for units with CXM board, ECM fan motor, and MPC (DDC) controls.

Control System Configuration

CXM Control Overview and Configuration

Details on CXM control operation, field selectable inputs, and configuration options.

DXM Control Overview and Configuration

Details on DXM control operation, field selectable inputs, and configuration options.

Safety Features - Control Systems

Anti-Short Cycle and Fault Protection

Protection features like anti-short cycle, random start, fault retry, and lockout modes.

Temperature Limit and Voltage Protection

Protection against low/high water/air temperatures and over/under voltage conditions.

Unit Performance Sentinel and ESD

Information on UPS feature indicating inefficiency and Emergency Shut Down (ESD) mode.

Diagnostic Features

Explanation of LED indicators on CXM and DXM boards for status and fault codes.

ClimaDry® Modulating Reheat Option

ClimaDry® Sequence of Operation

Explanation of how ClimaDry® operates in cooling, cooling with reheat, and heating modes.

ClimaDry® Component Functions

Description of components like proportional controller, sensors, and motorized valve in ClimaDry®.

ClimaDry® Application Considerations

Factors to consider when applying ClimaDry®, including EWT range and potential overcooling.

Starting and Operating Conditions

Environment and Power Supply Guidelines

Guidelines for unit installation environment and acceptable power supply voltage variations.

Operating Limits and Commissioning

Table detailing operating limits and commissioning conditions for cooling and heating modes.

Piping System Cleaning and Flushing

Flushing and Purging Units with ClimaDry®

Unit and System Checkout

Unit Checkout Procedures

Checklist for unit components and wiring before powering the system.

System Checkout Procedures

Checks for system water temperature, pH, flushing, and controls before operation.

Unit Start-up Procedure

Operating Conditions and Corrections

Motorized Water Valve Option Corrections

Corrections for operating conditions with motorized water valve options.

ClimaDry II Option Corrections

Corrections for ClimaDry II operation in non-ClimaDry mode, detailing additional water pressure drop.

Unit Operating Conditions Tables

Preventive Maintenance

Water Coil Maintenance

Procedures for maintaining water coils in direct ground water and other water loop applications.

Airflow and Drainage System Maintenance

Guidelines for filters, condensate drains, and pans to maintain performance and prevent issues.

Motor Maintenance

Annual checks for compressor and fan motor amperage draw and dry operation.

Air Coil Cleaning

Procedures for cleaning air coils to obtain maximum performance and avoid damage.

Refrigerant System Checks

Guidelines for servicing the refrigerant circuit while maintaining sealed integrity.

Functional Troubleshooting Guide

Main Power and HP Fault Troubleshooting

Troubleshooting steps for main power issues and high pressure faults (HP Fault Code 2).

Low Pressure and Temperature Faults

Troubleshooting steps for low pressure (LP/LOC Code 3) and low temperature (LT1/LT2) faults.

Condensate and Voltage Faults

Troubleshooting steps for condensate issues (Code 6) and voltage problems (Code 7).

Unit Operation and Short Cycling Issues

Troubleshooting unit short cycling, fan-only operation, or compressor-only operation.

Performance Troubleshooting

Insufficient Capacity Troubleshooting

Diagnosing and resolving issues related to insufficient cooling or heating capacity.

High Head Pressure and Low Suction Pressure

Troubleshooting steps for high head pressure and low suction pressure conditions.

Low Discharge Air Temp & High Humidity

Resolving issues with low discharge air temperature in heating and high humidity problems.

Start-Up Log Sheet

Troubleshooting Cycle Analysis

Warranty Information

U.S. & Canada Limited Express Warranty

Details the terms, limitations, and procedures for warranty claims in the US and Canada.

International Limited Express Warranty

Details the terms, limitations, and procedures for warranty claims outside the US and Canada.

Revision History

Related product manuals