31
Disposing of packaging
The packaging consists of cardboard and appropri-
ately marked films, which can be recycled.
– Take these materials to a recycling facility.
Troubleshooting
If something isn’t working…
Malfunctions are often caused by minor faults. You
can easily remedy most of these yourself. Please
consult the following table before contacting the
vendor. You will save yourself a lot of trouble and
possibly money too.
If you can’t fix the fault yourself, contact your nearest
vendor. Please be aware that any improper repairs
will also invalidate the warranty and additional costs
may be incurred.
Technical data
*) The stated values are emission values and do not necessarily
represent safe workplace values. Although there is a correlation
between emission and immission levels, it is not possible to
reliably derive whether additional precautions are necessary or
not. Factors influencing the immission level currently prevailing
at the workplace include the nature of the workroom, other
noise sources, e.g.the number of products and other work pro-
cesses. Admissible workplace values can also vary from coun-
try to country. However, this information should enable the user
to better assess danger and risk.
DANGER! Danger of death! Improper
repairs can result in the product functioning
unsafely. This endangers yourself and your
environment.
Fault/malfunction Cause Remedy
Motor not running. No mains voltage? Check cable, plug, socket and fuse.
Cable faulty? Contact a professional
Was the motor protection triggered? Remove all chipped pieces and
press reset button.
Was the safety switch not trig-
gered?
Check the connection hopper-mo-
tor housing.
Material to be chipped is not pulled
in.
Material blockage? Remove all chipped pieces from the
blades.
Are the blades blocked? Remove all chipped pieces and
press reset button
Are the blades worn? Replace the blades if necessary.
Rated voltage 220–240 V~, 50Hz
Rated output S6= (40%) 2400W
Protection class II
Degree of protection IP24
Idling speed 3940 min
-1
Max. branch width 40 mm
Sound pressure level (L
PA
)* 98dB(A)
(K = 3 dB(A))
Guaranteed sound power lev-
el (L
WA
)*
107dB(A)
(K = 1 dB(A))
Note: The product is intended for use only
in properties having a mains current carry-
ing capacity of ≥100A per phase and being
supplied by a distribution network with a
mains voltage of 400/230V. If required,
contact the electricity company to ensure
that the mains current carrying capacity at
the connection point to the public power
grid is adequate for connecting the prod-
uct.
GB