Chapter 3: Service & maintenance
Troubleshooting guide 27
33333
Service & maintenance
RX self test (with SAILOR 6004 Control Panel)
The RX self test runs automatically after start-up. You can also manually
start an RX Self Test directly from the display of the SAILOR 6004 Control
Panel. Do as follows:
1. From any list of messages (Unread, Tagged or All), tap the menu icon
and Settings.
2. Tap the menu icon again, then RX Self Test.
3. Tap Yes to continue.
4. Wait until the test is finished. The result of the test is shown in the
display. If the test has failed check the antenna installation.
If a printer is connected and enabled the self test results are printed.
5. Tap Close to return to the Settings page.
6. Tap the Back icon to return to the list view.
SAILOR 6004
Control Panel
cannot be
switched off.
If the SAILOR 6004 Control Panel cannot be
switched off normally (e.g. due to a fault): Push
and hold for 12 seconds. If a remote switch is
installed, see the note on page 5.
Password
entered in the
SAILOR 6004
Control Panel,
but padlock
does not open
Authorization
failed. Wrong
password or
the connection
to the
SAILOR 6390
Navtex
Receiver is lost
Check that you enter the correct password.
Check the power supplies, cabling, Ethernet
connection between the SAILOR 6390 Navtex
Receiver and the SAILOR 6004 Control Panel.
Restart both units:
– SAILOR 6390 Navtex Receiver: remove and
connect power,
– SAILOR 6004 Control Panel: use on/off
button.Password for SAILOR 6004 Control
Panel: user
RX self test
failed
Check the antenna installation.
Problem Symptom Remedy
Table 6: Troubleshooting guide (Continued)
98-137261.book Page 27 Wednesday, February 19, 2014 2:06 PM