7
D041878 CR5200 User Manual
5.0 - Using a CR5200
in Presentation Mode
6.0 - Using a CR5200
in Handheld Mode
JNR M NR PM QR
-15° 0° 15° 30° 45°
7.0 - Typical Reading Ranges
Note: All samples were high quality codes and were read along a physical center line at a 10° angle. Default automatic gain control setting
s
were used
with regular office lighting. Accuracy=
+/- 1
0%. Testing conditions may affect working ranges. Measured from the front of the
device in metric units then converted to Imperial units.
CR5200 Performance
Test Barcode Min Inches (mm) Max Inches (mm)
7.5 mil Code 39
0.4” (1
0 mm) 5.9” (150 mm)
10.5 Mil GS1 DataBar
0.4” (1
0 mm) 6.7” (170 mm)
13 mil UPC
0.4” (10 mm) 8.0” (203 mm)
5.8 mil PDF417
0.8” (20 mm)
4.0” (103 mm)
6.7 mil PDF 417
0.4” (10 mm) 4.8” (122 mm)
5 mil Data Matrix
1.2” (31 mm)
2.
3
” (59 mm)
6.3 mil Data Matrix
0.9” (23 mm)
3.
5
” (89 mm)
4 cm
10 mil Data Matrix
0.4” (10 mm) 5.7” (146 mm)
20.8 mil Data Matrix
0.4” (10 mm) 8.9” (225 mm)
Min Inches (mm) Max Inches (mm)
0.4” (1
0 mm) 5.1” (131 mm)
0.4” (
1
0 mm) 5.4” (138 mm)
0.4” (10 mm) 6
.8
” (175 mm)
0.
6
” (1
6
mm) 3.2
” (
82
mm)
0.4” (10 mm) 4.
5
” (1
14
mm)
1.0” (25 mm)
2.2” (55 mm)
1.1” (27
mm) 3.0” (
78 mm)
0.6” (1
4 mm)
5
.0” (126 mm)
0.4” (10 mm) 8.4” (213
mm)
Handheld Mode