0: Normal mode (buffered send)
1: Send and log mode
3: Log only mode
Note: Only applies to readers using Bluetooth® communication
modes.
Also see register: B4. Reader will not allow the user to set
auto-reconnect on, and store data. If any setting that allows
storing data is turned on, auto-reconnect will be turned off (if
it is on).
Keywords: #DataRetention
3: Settings locked (except settings Lock)
Tri-Optic Decoding, Normal
Quiet Zones
Reverse order of first and
second halves
Valid Range: Any event as defined in register 39 and re-listed
in C4
Motion detection is enabled by setting register C4 to 0xF0.
This register is reset to 0 (disabled) when register C4 is
changed away from 0xF0. When motion is detected, this event
is posted.
See register 39 or C4 for list of events.