Reg
Setting Name
Default (Hex)
Comment
9D
Target Tolerance
(percent)
640
(#1600)
Valid Range: 0 to 7FFFFFFF Percent
For the Reader to accept a barcode, the barcode must be
within a certain distance from the center of the image. The
distance is defined as a percentage of the barcode’s smaller
dimension. For example, with a 10 x 20 mm barcode and a
setting of 150 (%), the barcode must be within 15 mm of the
center of the image.
Any value over #1000 is considered infinite tolerance, and no
target checking is performed.
Keywords: #StandModes
9E
Extra Cabled Idle Time
CR2300:
CR2600:
CR2600XHD:
CR3600:
CR3600DPM:
2710 (#10000)
CR4405:
#-500
This is the time added to the idle timeout register 8E if unit is in
the charger. To disable this timer, set the register value to -1
as in the following example which disables and saves the timer
setting with the ‘C’ command:
C(9E)#-1
Current State: Idle
Next State: Standby
Note: Only applies to readers using Bluetooth® communication
modes.
Keywords: #ReaderState