CODEL Operation and Maintenance Manual
Issue : A Rev. : 3 Date : 13/11/2018 Ref. : 100351
P a g e | 7
3.5 Optional Items
24V DC Power Supply
Input:
110 - 240V AC @ 100W Max., 50/60 Hz
Output:
24V DC @ 60W
Dimension:
200 (L) x 230 (H) x 110 (D) (mm)
Colour:
Black (RAL9005 - Jet Black)
Construction:
Die-cast Aluminium
Enclosure Rating:
IP66 (IP69K Optional)
Weight:
4.0 kg
3.6 Output and Interface:
Analogue Outputs:
No.:
2 or 4
Type:
4-20 mA
Max. Load:
500Ω
Other:
Isolated, fully configurable for CO, NO and NO
2
Contact Output:
No.:
2 or 4
Type:
SPCO
Max. Load:
500mA @ 60V DC
Other:
Configurable as alarm contacts