3.5 PROJECTOR INSTALLATION
Tofix the MP700 Zoom is necessary, when theinstallation has to be
on a raised-from-the groundsupport, to block the quicklock/release brac-
kets of the unit by means of a screw provided with nutandlockn
ut measu-
ring not less than M10X50, to insertinthe central pre-arrangedholeonthe
fixingbracket.
Inaddiction to theprovidedquicklock/release (omega)brackets, in or-
der to guarantee a necessary security and in
respect of the actualsafety
rules concerning theprojectors’ installation, it is compulsory to install a sa-
fety-chain, equipped with two snaps, provided with theprojector, to con-
nect the MP700 Zoom‘s body to thefixingstructure.
ATTENTION:t
he safety chain, equipped with two snaps which can be
hooked to the two pivots placedunder the baseofthe MP700 Zoom,(see
part. A), must beproperly installed and fixed to the supportingstructure, in
away t
hat an incidentalgivin in of the main bracket would leed to the short-
estpossiblefall of theprojector. After such an intervention the safety-
chain must be replaced with another original part.
ATTENTION: COEF is not responsiblefor installations not correctly
madeor made without respecting theaboveindications:thoseinstallations
are considereddangerous.
3.2 OPERATING VOLTAGE
A
B
WARNING : unplug thefixturefrom the powersupply before operating.The operation must beperformed only
by highly specializedstaff.
WARNING : Thewrongselections of the operating tension and/or frequency compromisethe good operation of
thefixtureand will imme
diately invalid the COEF warranty.
3.3 Settings for magnetic ballast Cod. 02E010
3.4 Settings for electronic ballast Cod. 02E011
Thefixture can work at the
following tensions : 230 V~50 / 60 Hz
and 208 V~ 60 Hz(optional). Please
becareful to connect thecabletothe
rightterminal that isrelevant to the
desired tension and frequency; both
on the ballastand on thetransforme
r
located in the MP700Zoom base.
Pleasecarefully follow the
indicationsshown in the pictures A
and B.
Thefixture can work at thefollowing ten-
sions : 100V ~ 60 Hz, 120V ~ 60 Hz, 208 V
~50/ 60 Hz, 230 V ~50 / 60 Hz, 250 V ~50 / 60
Hz.
You can modify the settings following the
needs of theco
untry werethefixtureis instal-
led. This operation is easily done by moving
thecabletothe rightterminal of theelectro-
nic board transformer that islocated in the
baseofthefixture.The ballast (elect
ronic)does not need any adjustment.
We recommendyou to update the serigraphy tableatthe new value.