EasyManua.ls Logo

Coleman FC9M080C16UP11 - Page 4

Coleman FC9M080C16UP11
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
259720-CTG-B-0108
4 Unitary Products Group
For additional connection diagrams for all UPG equipment refer to “Line Voltage System Wiring” document available on-line at
www.upgnet.com in the Product Catalog Section.
Thermostat Chart - PSC Modulating Furnace/Single Stage Air Conditioner
AC 11A Single Stage Air Conditioner – PSC Modulating Furnace
FL9M
FC9M
PM9
ID MODELS
Part Numbers:
SAP = Legacy
155941 = 031-09140
1
C
24 – Volt Common
R
24 – Volt Hot
Y1
Single Stage Compressor
PSC
MODULATING FURNACE
G
Fan
PSC
MODULATING
FURNACE
Y/Y2
Second or Full
Stage Compressor
1
W
Modulating Heat
HM1
Humidistat
Y
Full Stage Compressor
G
Fan
*PP11C70224
THERMOSTAT
RH
24 – Volt Hot
(Heat XFMR)
RC
24 – Volt Hot
(Cool XFMR)
W
Full Stage Heat
Clipping Jumper W914 for
electric heat on thermostat
is not necessary
24VAC Humidifier
(Optional)
C
24 – Volt Common
Y
Compressor
SINGLE STAGE
AIR CONDITIONER
SINGLE STAGE
AIR CONDITIONER
Y
Compressor Contactor
SINGLE STAGE
AIR
CONDITIONER
SINGLE STAGE
AIR CONDITIONER

Related product manuals