3.2.3. Grounding
Grounding must be carried out. Connect an earth-bonding cable to the grounding
connection provided at the outside of the Remote Unit (see chapter 3.2.2
Connections). Do not use the grounding connection to connect external devices.
figure 3-6 Grounding bolt figure 3-7 Grounding bolt, schematic view
After loosening the hex nut, connect the earth-bonding cable between the two
washers as illustrated in the figures above. Then, fasten all parts again with the hex
nut.
3.3. CONNECTION OF THE ANTENNA CABLES
The Remote Unit has 7/16-type antenna connectors. Please refer to section 3.2.2
Connections for its location. Refer to the corresponding documentation of the
connector manufacturer for mounting the cable connectors.
The bending radius of the antenna cables must remain within the given
specifications.
Consider the type of cable best suited for the antenna. Remember that a cable with
higher loss is less expensive but impairs performance.
Use an appropriate torque wrench for the coupling torque (25 N-m / 19 ft
lb) of 7-16 DIN connectors with 1-1/4 in opening to tighten the 7/16-type
antenna connectors. For example, use torque wrench of item no. 244377
available from the Andrew e-catalog. Do NOT use your hands or any
other tool (e.g. a pair of pliers)! This might cause damage to the
connector and lead to a malfunction of the Remote Unit.