INS_FDW1000_EXP101 01/06/2020 PAGE 26
INSTALLATION AND OPERATION MANUAL FDW1000 / EXP101
TECH SUPPORT: 1.888.678.9427 / +44 (0)203 630 1653
DIP Switch 1
is reserved
for factory use.
DIP Switch 2 sets
the EXP to Central
or Remote mode.
DIP Switches 3,
4, and 5 set the
data interface.
DIP Switches 6,
7, and 8 set the
polling address.
Polling Address Select
6 7 8
0 0 0 not used
0 0 1 Address 1
0 1 0 Address 2
0 1 1 Address 3
1 0 0 Address 4
1 0 1 Address 5
1 1 0 Address 6
1 1 1 Address 7
Data Interface Select
3 4 5
0 0 0 not used
0 0 1 Wiegand
0 1 0 Wiegand No Filter
0 1 1 Strobed Rising (MR5)
1 0 0 Strobed Rising (Dorado 644)
1 0 1 Strobed Rising (Mag-Tek)
1 1 0 Strobed Falling
1 1 1 Unsupervised F/2F
Central / Remote Select
2
ON Central
OFF Remote
EXP101
Programming