Wearing appropriate personal safety equipment is
recommended while loading CNG. Gloves, safety glasses and/or face
shield, hearing protection and non-static generating clothing should be
worn. Vehicles should be switched off and any potential sources of ignition
removed.
Refer to hydraulic diagram for the function of the valves. Hydraulic Layout -
Loading Post (see page 54).
To use the CNG Loading Post:
1. Check that the inlet valves IV1 (inlet) and IV2 (outlet) are open and
vent line valve is closed.
2. Press the Start button. The display will show 888888 and then clear,
at this point both the gas and value totals will display 0.00
3. Connect the refuelling nozzle to the vehicle
4. Open the refuelling nozzle valve to commence filling.
5. The dispenser will emit a long beep signalling the end of the fill, at this
point the gas total display flashes Fin.
6. Close the refuelling valve.
Closing the valve shuts off the gas from the dispenser. It
also vents the gas between the refuelling valve and coupling to the
dispenser vent point.
7. Disconnect the nozzle from the vehicle.
8. Return the refuelling nozzle to the nozzle holder.