12. MAINTENANCE
12.1. General warning
Before performing any type of maintenance:
Always turn off the main power switch to the OFF position ( ).
If the grinder is jammed, unplug it from the power source and contact an
authorized service technician.
Not following these warnings can compromise the safety of the grinder as well as
the user.
12.2. General maintenance of the grind chamber
To guarantee the efciency and correct operation of the grinder, it is essential to
follow manufacturer instructions and ensure that all maintenance work is carried
out by qualied staff.
Dull burrs will result in a lower quality grind, greater heat generation in the coffee
and grinder, increased electrical consumption, and nally it puts additional stress
on the grinder motor.
NOTE: Based on extensive experience and a medium-hard coffee blend, we
recommend replacing the burrs following the quantities in next table:
Steel Red Speed Lucidate
F8 OD
800 Kg 3500 Kg
F10 CONIC OD
1200 Kg 7500 Kg
F10 MASTER CONIC OD
1200 Kg 7500 Kg

Related product manuals