1782 - Disk None Fixed disk drive 1. Run Diagnostics.
Controller controller error 2. Check and/or
Failure replace the power
distribution board.
3. Replace the fixed
disk drive.
-----------------------------------------------------------------------------
Message Beeps Probable Cause Recommended Action
-----------------------------------------------------------------------------
1790 - Disk 0 Error None Fixed disk drive 1. Run Diagnostics.
error or wrong 2. Replace the
drive type drive.
-----------------------------------------------------------------------------
1791 - Disk 1 Error None Fixed disk drive 1. Run Diagnostics.
error or wrong 2. Replace the
drive type drive.
-----------------------------------------------------------------------------
XX000Y ZZ Parity None Parity RAM Run Diagnostics.
Check 2 failure
-----------------------------------------------------------------------------
Audible 1 Short Power on None.
successful
-----------------------------------------------------------------------------
Audible 2 Short Power on None.
successful
-----------------------------------------------------------------------------
(RESUME = None As indicated Press F1 key
"F1" KEY) to continue.
=============================================================================
Cha
p
ter 3.2 Dia
g
nostic Error Codes