1719 - 47 Failed to park heads
1719 - 48 Failed to move disk
table to RAM
-----------------------------------------------------------------------------
Error Recommended
Code Description Action
-----------------------------------------------------------------------------
1719 - 49 Failed to read media in The following steps apply
file write test to error codes 1700 - xx
through 1719 - xx:
1719 - 50 Failed file I/O write test 1. Replace the fixed disk
drive and retest.
1719 - 51 Failed file I/O read test 2. Replace the power
distribution board
1719 - 52 Failed file I/O compare test and retest.
3. Replace the I/O board
1719 - 53 Failed drive/head and retest.
register test
1719 - 54 Failed digital input
register test
1719 - 55 Failed cylinder 1
1719 - 56 Fixed disk drive controller
RAM diagnostics failed
1719 - 57 Fixed disk drive
controller to drive
test failed
1719 - 58 Failed to write sector
buffer
1719 - 59 Failed to read sector
buffer
1719 - 60 Failed to compare sector
buffer
1719 - 61 Failed uncorrectable
Error Correction Code error
-----------------------------------------------------------------------------
Error Recommended
Code Description Action
-----------------------------------------------------------------------------
1719 - 62 Failed correctable Error The following steps apply
Correction Code error to error codes 1700 - xx
through 1719 - xx:
1719 - 63 Failed soft error rate 1. Replace the fixed disk
and retest.
1719 - 65 Exceeded maximum 2. Replace the power
bad sector per track distribution board
and retest.
1719 - 66 Failed initial drive 3. Replace the I/O board
parameter and retest.
1719 - 67 Failed to write long