EasyManuals Logo

Computer Automation CAT-200B User Manual

Default Icon
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
3-5
8. Link Time-out Enable
Link time-out is user programmable with the [*602*] timer programming commands. When the CAT-
200B is initialized, this timer defaults to 3 minutes. When this channel is turned off, the repeater will not
time-out.
Zone 3 – Logic Inputs – Switch Outputs
1. Logic Input #1 Enable
When this channel is enabled, a logic active high input on connector J3-1 will activate voice message #3.
This message is user programmable. The default message is “EMERGENCY POWER”.
2. Logic Input #2 Enable
When this channel is enabled, a logic high input on connector J3-2 will activate voice message #4. This
message is user programmable. The default message is “WEATHER ALERT”.
3. Logic Input #3 Enable
When this channel is enabled, a logic high input on connector J3-21 will activate voice message #5. This
message is user programmable. The default message is “INTRUDER ALERT”.
4. Logic Input #4 Enable
When this channel is enabled, a logic high input on connector J3-22 will activate voice message #6. This
message is user programmable. The default message is “HIGH TEMPERATURE”.
5. Switch #1 Enable
When this channel is enabled, switch #1 is turned on. Connector J3 pin 14 will sink 50 MA to ground.
6. Switch #2 Enable
When this channel is enabled, switch #2 is turned on. Connector J3 pin 15 will sink 50 MA to ground.
7. Switch #3 Enable
When this channel is enabled, switch #3 is turned on. Connector J3 pin 19 will sink 50 MA to ground.
8. Switch #4 Enable
When this channel is enabled, switch #4 is turned on. Connector J3 pin 20 will sink 50 MA to ground.
Zone 4 - Miscellaneous Control
1. DTMF Pad Test Enable
When this channel is enabled, a repeater user is able to perform a test of their radio's 12 or 16-button
keypad. As the numbers are being decoded, they are stored in memory. When the repeater user stops
transmitting the controller will read back all the numbers that were decoded.
2. Beacon Mode
When this channel is enabled and there is no activity on the repeater, the CAT-200B will announce voice
message 7 at an interval rate determined by the Beacon Timer [*605*]. Message 7 defaults to: “CAT-
200B BEACON.” The Beacon Timer defaults to one minute.
3. Weather Report Enable
When this channel is enabled, a repeater user is able to request a weather report.