5-4
Read Control And Prefix Numbers [*501 - *508]
Use this programming command to read the control operator and prefix numbers. Example: Key-up and
enter [*501], un-key and the voice will say: "CODE FIVE ZERO ONE IS ONE ZERO ZERO."
Timer Memory
This memory area is reserved for storage of [8] timers. These timers are user programmable. When the
CAT-200B is initialized, these timers are automatically loaded with default values.
Repeater Time-out [*601*]
This timer limits the length of a transmission. This timer is programmable between 60 and 1799
seconds. Example: To program the timer for 3 minutes, key-up and enter [*601*180]. Un-key and the
voice will say: "CONTROL OK." When initialize, this timer defaults to 180 seconds.
Link Time-out [*602*]
The link time-out timer limits the maximum length of a transmission. This timer is programmable
between 60 and 1799 seconds. Example: To program the timer for 3 minutes, key-up and enter
[*602*180]. Un-key and the voice will say: "CONTROL OK." When initialize, this timer defaults to 180
seconds.
Repeater ID Timer [*603*]
This timer sets the time between transmissions of the repeater ID. The ID occurs when a repeater user
stops transmitting. This timer is programmable between 60 and 1799 seconds. The timer default is 480
seconds.
Link Auto Disconnect Timer [*604*]
During link operation if Zone 2 channel 6 is enabled the link will disconnect automatically after a period
inactivity. This timer is programmable between 60 and 1799 seconds. The timer default is 600 seconds.
Beacon Mode Timer [*605*]
When Zone 4 channel 2 is enabled and the repeater is inactive, the CAT-200B will automatically transmit
voice message 7. The message will repeat per the setting of this timer. This timer is programmable
between 60 and 1799 seconds. The timer default is 60 seconds.
Logic Input Message Timer [*606*]
This timer sets the time between logic input message announcements. The messages will continue to
repeat as long as the respective logic input remains active high. This timer is programmable between 60
and 1799 seconds. The timer default is 600 seconds.
COR Drop to Courtesy Beep Timer [*610*]
This timer determines the time between loss of COR and the generation of the courtesy beep. This timer
is programmable between 0.1 and 9.9 seconds. The timer default is 1 second.
Courtesy Beep to PTT Drop Timer [*611*]
This timer determines the time between the generation of the courtesy beep and the time
the repeater
transmitter turns off. This timer is programmable between 0.1 and 9.9 seconds. The timer
default is 4 seconds.