OPERATING & INSTALLATION INSTRUCTION 2-POST-LIFT
Manual arm lock override
Manual arm lock
override
Accessories
Order-no. 34990.2
Manual of arm lock override
Remove cover tape, so that you can see the spindle
Put the lever through the front of the hole of the
carriage
Please check the lever. The U-profile have to set
down on
the first threat bar.
Screw the lever on the guide bar (2x)
Screw the guide bar in the threated bore of the lever
(7 mm deep). (2x)
Screw the arm lock override of its function
Fasten the cover tape with the metal stripe and the
nuts again.