Edition 05/2021 CC200 D Notice technique page 15
SACOME, Document CONFIDENTIEL, Ne peut être reproduit ni communiqué sans notre accord préalable.
9.2. EXPLANATION FOR THE PROGRAMMING STEPS OF THE TECHNICAL MENU:
Language:
There are 4 languages available : ENGLISH (GB-USA) FRENCH (F) GERMAN (G) ITALIAN (I).
Water counter:
This menu is dedicated to the water softeners system.
This step allows to see the quantity of water consumed (in liter, from 0 to 9999 liters) by the machine
from the last water softener installation.
The quantity of consumed water is made of:
Coffee water going throught the flowmeter.
The water interring in the boiler.
To escape, youneed to press MENU.
Coffee counters:
Allows partial reading of doses distributed cafes.
Press ENTER to access the menu Counters.
Press MENU to see each key, the display shows:
Cumulative total cycles number (service purpose).
espresso number (1 small cup) on group 1, 2 and 3
2 espresso number (2 small cups) on group 1, 2 and 3
coffee number (1 large cup) on group 1, 2 and 3
2 coffees (2 large cups) on group 1, 2 and 3
NB:
- The counter goes up to 65535 for each button. Then it restarts from 0.
- A distribution is accounted for 1 time for keys " P1 Grx " or "P3 Grx" or "P5 Grx" and 2 times for the keys "
P2 Grx " and "P4 Grx" when you press a key.
Explanation about counters reset:
Coffee counter reset: when the display shows «Cumulative total», press "P4 Gr1" for 3 seconds,
the display shows then « Total Reset ».
Only the counters of each key is reset. The total counters of products is not reseted.