Product information
- 12 -
EN
1. Setting up the appliance
Appliance dimensions:
Without
packaging
With
packaging
Width
515 mm 580 mm
Depth
599 mm 730 mm
Height
627 mm 800 mm
Weight
45 kg 60 kg
• Appliance must be installed level
Safety distances:
• Left-right : 50 mm
• Back : 50 mm
• Above : 500 mm (ventilation)
2. Connecting to the electrical supply
Either alternating current 1/N/PE 230V 50/60Hz
or three-phase current 3/N/PE 400V 50/60Hz
(can be converted on site by CONVOTHERM
authorised service partner)
1/N/PE
230V
3/N/PE
400V
Connected wattage [ kW]
3,0 5,7
Rated current [A]
13,1 11,8
Cable cross section* [mm²]
3 x 2.5 5 x 2.5
* recommended cable cross section open-air laid
at max. 5 m in length.
• Main switch (all-pole separator) is to be
installed by the customer in the vicinity of the
appliance.
• Connection for potential compensation.
• WARNING 1/N/PE connection causes
considerable power reduction and therefore
extension of the cooking time.
3. Connecting to the water supply:
• Cold water ¾” 2 to 6 bar flow pressure
• Water tap and filter are to be installed by
the customer in the vicinity of the
appliance
• Water: Drinking water quality with
Total hardness: 5-7°dH
(soft water)
pH: 6.5 to 8.5
Conductivity: 10-200µS/cm
Cl
-
: max 100mg/l
SO
4
-
: max 400mg/l
Fe: max 0.1mg/l
Mn: max 0.05mg/l
Cu: max 0.05mg/l
Cl
2
: max 0.1mg/l
if necessary, install water treatment
4. Water drainage
DN 40, recommended tundish funnel or
fixed connection
5. Ventilation
Sensible heat output 1100 kJ/h
Latent heat output 1000 kJ/h
6. Other data:
Splash protection IPX4
Conformity marking CE
Noise emission: < 70 dBA
Inserts 2/3 GN (325x354mm) 6
Shelf spacing 50 mm