Cleaning and Maintenance
minis user manual 130
► Rectifying faults - Irregularities during operation
Errors and required responses
The following table contains a list of possible irregularities during operation and how to rectify them:
Irregularity Possible cause Required response
Suction panel not closed correctly
Removing and fitting the suction panel on
page 140
Air guide panel not fitted correctly or
not fitted at all
Fixing the air guide panel to the rack on
page 136
Oven compartment not preheated Preheat the oven compartment
Uneven browning
Oven temperature too high
Select a lower oven temperature and
extend the cooking time
Appliance does not respond to
any inputs on the screen
Software has crashed
Press ON/OFF for 5 seconds or discon-
nect the appliance from the mains supply
for 5 seconds
No longer able to switch the
appliance on or off
ON/OFF is blocked for 3 seconds Try again after 3 seconds.
Whatever the cause
Caution: risk of contamination:
Discard any food that has come into
contact with this water.
Complete or partial blockage of
waste water pipe
Permanent drain connection on
appliances with CONVOClean sys-
tem
Check customer's drain system and clean
if necessary
Use permanent connection if applicable
Air vent blocked or covered Remove obstruction
Water runs out underneath the
appliance when closing the
door
Appliance drain clogged Clean out the drain
Water standing in oven com-
partment
Appliance drain clogged Rinse out the drain
White marks in the oven
compartment
Limescale on oven compart-
ment wall
Water too hard
Adjust water hardness, see Technical
data on page 16
Black marks in the oven
compartment
Incorrect cleaning agent
Use CONVOClean forte for automatic
cleaning
Use CONVOClean forte or CONVOClean
new for semi-automatic cleaning
Water pressure too low Testing the water pressure
If necessary, increase the customer's
water pressure
Incorrect soiling level set Select a higher cleaning level
Poor cleaning result
Incorrect cleaning agent used
Use CONVOClean forte for automatic
cleaning
Use CONVOClean forte or CONVOClean
new for semi-automatic cleaning