Questions and Answers

  • C
    Chad StevensAug 19, 2025
    What does Drive ERROR mean on my Cornelius FCB - 2 Flavor?
    • J
      jennifer03Aug 19, 2025
      A Drive ERROR on your Cornelius Beverage Dispenser can indicate: * The motor is not turning when commanded to, possibly due to a freeze-up. Check the Brix, check if sold out, check for a leaking pulse valve, a defective binding magnet, or a broken beater bar. * A bad inverter board (Emerson). Test and replace as necessary.
  • R
    Richard WatkinsAug 21, 2025
    What does Low/High voltage ERROR mean on Cornelius FCB - 2 Flavor?
    • J
      Joseph HamiltonAug 21, 2025
      A Low/High voltage ERROR on your Cornelius Beverage Dispenser means: * The line voltage is out of specification (198-253 VAC for 60 Hz and 196-265 VAC for 50 Hz). Check the line voltage and check T1/T2 with the compressor running. * The error range is 180/260. Correct the line voltage.
  • T
    Timothy HamptonAug 25, 2025
    What causes a Torque ERROR on a Cornelius Beverage Dispenser?
    • B
      browndanielleAug 25, 2025
      A Torque ERROR on your Cornelius Beverage Dispenser can be caused by: * A freeze-up, which may indicate a defective pulse valve. * Misalignment of the magnet and stator; ensure the stator or magnet is installed correctly. * Magnet binding; inspect and correct the problem.
  • E
    ethanthomasAug 26, 2025
    What to do if there is a problem with the hot gas valve on my Cornelius FCB - 2 Flavor?
    • J
      Julie GonzalezAug 26, 2025
      If you're experiencing issues with the hot gas valve on your Cornelius Beverage Dispenser: * Correct any miswiring. * Replace the coil if it is defective. * Replace the product delivery board if it is defective.
  • K
    Katie MonroeAug 28, 2025
    What does Electronic ERROR mean on my Cornelius FCB - 2 Flavor Beverage Dispenser?
    • H
      haysmitchellAug 28, 2025
      An Electronic ERROR on your Cornelius Beverage Dispenser may indicate: * A clock chip issue or bad line frequency. Replace the clock chip. * Faulty communication. Check the phone connections.
  • D
    Daniel ButlerAug 30, 2025
    Why won't my Cornelius FCB - 2 Flavor run?
    • T
      Tonya HicksAug 30, 2025
      Your Cornelius Beverage Dispenser might not be running due to several reasons: * It may not be plugged in; ensure the unit is properly plugged in. * The circuit breaker may have tripped; try resetting or replacing the circuit breaker. * There might be no power at L1 or L2 on the contactor; check the voltage at the outlet and the wiring to the contactor. * Low voltage at T1 or T2 may be the cause; in this case, replace the contactor. * A solid red LED above the display indicates a serious issue; if this LED is lit, do not restart the dispenser and immediately call Service at (800) 238-3600.
  • R
    robert97Sep 1, 2025
    What to do if the compressor is not running on my Cornelius Beverage Dispenser?
    • W
      Wesley WilliamsSep 1, 2025
      If the compressor on your Cornelius Beverage Dispenser isn't running, consider these potential causes: 1. The cylinder might not be in ON mode; ensure the cylinder is turned to ON. 2. There might be no voltage to the compressor; check the power at contactor L1, L2 - T1, T2. 3. The start components could be faulty; inspect the components and wiring. 4. The compressor’s thermal overload protector might be open; check the resistance of compressor windings and incoming line voltage. 5. There could be open or shorted compressor windings; check the resistance of compressor windings. 6. The control board might be bad; troubleshoot and replace if necessary.
  • B
    Brian TerrellSep 3, 2025
    Why is my Cornelius FCB - 2 Flavor Beverage Dispenser compressor running but not cooling?
    • C
      Chelsea FletcherSep 3, 2025
      If your Cornelius Beverage Dispenser's compressor is running but not cooling, the following could be the reasons: * Low refrigerant: Repair the leak and weigh in a new charge. * Restricted condenser/filter: Clean or repair. * Defective condenser fan motor/blade: Repair or replace. * Any pulse valve stuck open or closed: Replace. * Hot gas valve leaking or open: Repair or replace. * Defective compressor: Repair or replace.
  • M
    Monica WarnerSep 5, 2025
    How to fix restricted air flow in Cornelius Beverage Dispenser?
    • M
      Megan MartinSep 5, 2025
      To fix restricted air flow in your Cornelius Beverage Dispenser: * Clean a dirty filter. * Clean a dirty condenser. * Repair/replace damaged fins, if necessary. * Ensure proper spacing around the unit.
  • C
    Chad RossSep 7, 2025
    Why is the barrel status OFF #1 and #2 on my Cornelius FCB - 2 Flavor?
    • V
      vtaylorSep 7, 2025
      The barrel status being OFF #1 and #2 on your Cornelius Beverage Dispenser can be due to these reasons: * The barrel is not activated; turn it to ON or MOTOR mode. * An error has shut off the motors; correct the error and turn to ON or MOTOR mode. * The unit is in Diagnostics mode; exit diagnostics and turn to ON or MOTOR mode. * A defective touch switch; replace it.