Why is my Cornelius Beverage Dispenser not dispensing carbonated drinks and only syrup?
- BBill KingAug 19, 2025
This issue may arise if the CO pressure in the carbonator tank is too high. In this case, check the CO pressure regulator setting, a setting of 75 psig is recommended, and relieve pressure from the carbonator tank. Another potential cause is a water valve that won't open. Inspect the electrical connection to the water valve, check the coil's resistance (it should be 9 ohms), and verify voltage at the coil when the brand button is pressed.