10
1-11. Read Input Register (R)
FUNC
CODE
Starting
Address
Description
number
of word
to read
Command
and
Response
Example
calculation
of value
4
0x0030
Real time output voltage
(RV?)
1
A0 04 00 30 00 01 28 B4
A0 04 00 30 04 DB AB EF
0X04DB =
1243
12.43V
0X0031
Real time output current
(RI?)
1
A0 04 00 31 00 01 79 74
A0 04 02 0B B6 82 6F
0X0BB6 =
2998
For
model12~57
V,its
29.98A
For model
120V~400V
,its
2.998A
0x0032
Response output
power(RP?)
1
A0 04 00 32 00 01 89 74
A0 04 00 32 00 96 C8 DA
0X0096 =
150
150W
0x0033
Temperature of NTC1 on
PFC(NTC1?)
1
A0 04 00 33 00 01 D8 B4
A0 04 00 33 FF EC 19 49
0XFFEC (It
is negative
number)
0XFFFF-0X
FFEC=0X13
-20