18
Response Frame:
1-14. Write Single Register
FUNC
CODE
Starting
Address
Desc
Write
number
of byte
CMD AND RESPONSE
Value
6
0X0001
Setting output voltage
2
A0 06 00 01 04 B0 C2 0F
A0 06 00 01 04 B0 C2 0F
Set 12.00V
1200(DEC)=0
X04B0(HEX)
0X0002
Setting output current
2
A0 06 00 02 03 E8 31
C5
A0 06 00 02 03 E8 31
C5
For model
12~57V.
It’s
Set 10.00A
For model
120~400V.It’
s
Set 1.000A
1000(DEC)=
Slave Address
1 Byte
0XA0 (AD Default Address)
Function Code
1 Byte
0x06
Register Address MSB
1 Byte
0x00
Register Address LSB
1 Byte
0x00 to 0xFF
Register Value MSB
1 Byte
0x00 to 0xFF
Register Value LSB
1 Byte
0x00 to 0xFF
CRC LSB
1 Byte
CRC MSB
1 Byte