14
0X0068
Read Modbus ID of
Slave(Master only)
4
A0 04 00 68 00 04 69 64
A0 04 08 A0 00 00 00 00
00 C7 E8 7A F5
0X0069
Read All Output
Voltage(Master
Only,M&1~7Slave)
8
A0 04 00 69 00 08 38 A1
A0 04 10 12 BD 00 00 00
00 00 00 00 00 00 00 12
BC 12 BF B2 99
0X0070
Read All Output
Current(Master Only)
8
A0 04 00 70 00 08 E9 66
A0 04 10 00 01 00 00 00 00
00 00 00 00 00 00 00 00 00
00 0B C9
0X0071
Read ID code and S/N
7
A0 04 00 71 00 07 F8 A2
A0 04 0D 4D 30 54 32 32
35 35 31 30 32 37 37 30 D0
B1
0X0072
Read Slave
S/N1~4(Master Only)
24
A0 04 00 72 00 18 49 6A
A0 04 30 54 32 32 35 35 31
30 32 37 37 31 A2 00 00 00
00 00 00 00 00 00 00 00 00
54 32 32 35 35 31 30 32 37
37 33 A3 54 32 32 35 35 31
30 32 37 37 34 A4 EE 33
54 32 32 35
35 31 30 32
37 37
31(hex)
Slave1
SN:T225510
2771
A2
Slave1
ID:A2(hex)-
>162