32
Ref.1
POWER x
0
setting power "off" and force to remote control
1
setting power "on" and force to remote control
Ref.3
ERR1?
Comments
bit
Decimal
ERROR
LED Status
0
1
Communication Fail
Power_Fail
1
2
Primary side PFC stage build
bus time out(P_PFC_TOUT)
Power_Fail
2
4
Primary side Rectifier stage
build bus time
out(P_REC_TOUT)
Power_Fail
3
8
Primary side Bus Over
Voltage
Protect(P_BUS_OVP)
Power_Fail
4
16
Primary side Grid Over Load
Protect(P_GOLP)
AC_Fail
5
32
Primary side Grid Over
Current Protect(P_GOCP)
AC_Fail
Ref.2
REMS x
0
Setting operation in Local mode
1
Setting operation in Remote mode
2
Setting operation in Charger mode (Reserved or coming soon!)
3
Setting operation in Programmable mode (Reserved or coming
soon!)