EasyManua.ls Logo

Cotek S Series - S300 Specification

Cotek S Series
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
2-4. S300 Specification
Specification
Model No.
Item
S300-112
S300-124
S300-212
S300-224
AC Voltage
100 / 110 / 120 VAC ± 5%
220 / 230 / 240 VAC ± 3%
Rated Power
300W
Surge Power
400W
Waveform
Pure Sine Wave (THD < 6.0%)
Frequency
50 / 60Hz ± 0.5%
Power Factor Allowed
cosθ -90° ~ cosθ +90°
Standard Receptacles
GFCI / NEMA
Schuko / Australia / UK /
Universal / IEC
No Load Current Draw
0.24A
0.28A
0.26A
0.28A
DC Voltage
12V
24V
12V
24V
Input Voltage Range
10.5~15.0
VDC
21.0~30.0
VDC
10.5~15.0
VDC
21.0~30.0
VDC
Efficiency (Typ.)
89%
89%
89%
89%
Protection
Overload, Short Circuit, Reverse Polarity (Fuse),
Over / Under Input Voltage, Over Temperature.
Remote Control
Yes, On/Off controlled by external switch
Working Temperature
0 ~ 40 ɗ
Storage Temp. &
Humidity
-30 ~ 70ɗ, 10~95% RH
Safety Standards
Certified UL 458
(Only for GFCI receptacles)
Certified EN 60950-1
Isolation Resistance
I/P O/P: 100M Ohms / 500VDC
EMI Conduction &
Radiation
Certified FCC class B
Certified EN 55022;
EN 61000-3-2, -3-3, -6-3;
EN 61204-3
EMS Immunity ----
Certified EN 61204-3;
EN 61000-6-1;
EN55024; ENV50204;
IEC 61000-4-2, 3, 4, 5, 6, 8, 11
E-mark ----
Certified CISPR25
ISO 11452-2; ISO 7637-2
Fan Cooling
Thermostatically controlled
Dimensions (WxHxD)
154x73x215 mm / 6.06x2.87x8.46 inch
Weight
4.06kg
NOTEThe specifications are subject to change without notice.