安全提示
No.:JT190100017 Version No.:A0
Note: The subsequent versions of this manual are subject to change without notice, thank you
10 / 21
theevaporator;
13.3 Sink cleaning
Press the” ” key to be in standby mode, the
screen displays "OFF", unplug the power plug, use
a screwdriver to remove the two screws on the water
pump box, loosen the three screws on the inner wall
of the ice storage bucket, remove the clamp, The
connectors at the lower and upper water pipes,
water pump and float can be removed and cleaned;
Use a soft material such as a brush or sponge
dipped in descaling agent or vinegar to scrub the
sink.
13.4 Condenser cleaning
It is recommended to clean the condenser every
six months, and follow the steps below : Remove
the hand screws on the left and right sides under
the ventilation window and take down the
ventilation window;
!Warning
To clean the condenser, the ice maker
must be disconnected from the power
supply. The edge of the condenser is
sharp, so be careful of cuts when
cleaning.
★Important
Dirty condensers will block the air
circulation, causing the ice maker to
operate at an excessively high
temperature, reducing ice production and
shortening the service life of parts.